The configuration of the CAP 28 WA Hair should be built from the distinction between standard and optional. The official card declares 8.15 meters, 2,79 meters of glare, eight or ten people, about 2,100 kg dry, maximum 450 hp outboard and CE B/C certification. It does not publish speed or consumption: the audit must focus on identifiable components, accessibility of plants and recorded tests on the specimen.
Official data to be reported in the minutes
| Control | Summary |
|---|---|
| Length outside everything | 8,15 m |
| Maximum | 2,79 m |
| Persons | 8/10 |
| Dry weight | about 2.100 kg |
| Maximum power | 450 hp |
| Propulsion | outboard |
| Category CE | B/C |
| Fuel | about 450 l, standard |
| Showers | about 70 l, standard |
| Refrigerator | about 48 l, standard |
The minutes must keep the qualification “about” where it appears. Operating weight includes propellers, liquids, batteries, accessories and load. Also the indications B/C and eight or ten people require control of the plate and documentation of the unit. The commercial page directs the verification, but does not replace manual, declaration and separate signed.
First separation: equipment and accessories
The standard includes bench with gavone, bilge, compass, detachment, picture, winch, sunscreen, refrigerator, fuel tank, hydraulic steering, toilet, lights, radio, shower, console, ladder and teak table. The other components listed are optional. Two signed columns avoid equivocs and allow you to connect any brand, model, serial, protection and installation responsibility.

Electrical panel and circuit identification
The picture is standard, but the source does not specify voltage, capacity of the batteries or scheme. It is therefore necessary to identify sources, detachment, protections and wiring on the specimen. Each command is tried separately and under load when appropriate, annoting missing labels or added utilities. Terminals, passages and fuses must be protected and accessible. No electrical autonomy can be deducted without real battery data and absorption measures.
Battery and rest status
The battery is included in the standard. The verification sequence checks location, legibility, locking and behaviour of the circuits in the different conditions. We must clarify the utilities that are eventually fed, without assuming them. The owner receives a stop and reactivation procedure consistent with manuals and installation. After remittance, charge, terminals and abnormal absorptions are checked, recording dates and interventions.
Sentry and discharge pump
The bilge pump is standard. It is located the lowest point served, you control cleaning, fixing, pipe, clamps and unloading, then you try automatic and manual operation according to a safe procedure. Access must allow maintenance. After the exit, reopen the compartment to search for inputs or residues. The only ignition of the electric motor does not show that the water is evacuated correctly.

Fuel tank of about 450 liters
The standard capacity is indicated in about 450 liters. The verification searches plate, material, year, vent, vent, indicator, pipes, filters and accesses of the unit, without inventing details absent from the source. Odours, rubbish and seal are observed. Autonomy requires usable volume, measured consumption and reserve; it cannot be obtained from capacity alone. The calibration of the indicator should also be checked progressively during use.
Outboard up to 450 hp
The official maximum power is 450 hp, but engine or actual engines must be identified by model, serial, weight, year and propeller. They control mounting, bolting, steps, pipes, cables and freedom of movement with steering and trim. The maximum limit is not a promise of performance. A test records people, fuel, equipment, sea, wind and regime, keeping each result tied to that configuration.

Standard hydraulic steering
Hydraulic steering is included. Cylinder, pump, tubes and fluid are identified on the specimen; losses, games, rubbing and folds are sought. The steering wheel must move regularly from bar to bar with outboards in the planned positions. SeaStar assistance is one of the options and should not be installed. Distinguished and tested must clearly distinguish basic system and any additional assistance.
Compass, lights and radio
Compass, navigation lights and radio are standard, but the page does not provide brand or model. The lights are lit individually and controlled for fixing and visibility; the compass for legibility and possible interference. The radio must have identification, manual, protection and loudspeakers. Equipment installed after delivery can change wiring and magnetic environment: for this the console must be verified as a single system.

Electric stream and bow area
The electric winch is supplied base. You control brand, model, command, protection, wiring, fixings, chain or top and access to the rack. The test is safe, also checking the manual recovery provided by the installed product. The standard prodier cuscineria should not hinder operations or inspections. After use, drainage and mooring line are observed, avoiding accumulations that can block the operation.
Standard refrigerator for about 48 liters
The refrigerator is declared in about 48 liters. The verification sequence identifies the model, closing test, ventilation and cooling, then measures or documents absorption. Opening and maintenance must live with the steps. The capacity does not indicate energy autonomy: it serves actual batteries, temperature and duration of use. A refrigerator on for a few minutes does not show a stable performance; testing must have sufficient time and noted conditions.

Shower and water circuit from about 70 liters
The standard shower is associated with about 70 liters. Reservoir, vent, vent, pump, pipes, control and dispenser are located. The plant is filled and pressured, controlling leaks, spontaneous alerts and drainage of the area. Nominal capacity and usable volume do not automatically match. Before remittance, emptying and protection procedure must be noted, with cleaning registration and periodic checks.
Marine toilet with tank
The toilet and its tank are standard. The control involves pump or control actually present, pipes, valves, vents, accesses and seals, without attributing an undeclared technology. It is tested according to manual use and is cleared emptying, cleaning and prolonged inactivity. The environment must allow inspection of components. Documentation and explanation to the owner are part of the testing, not an optional addition.

Optional dock and boiler
The power outlet from dock to 220 V and the boiler from about 25 liters to 220 V are optional. If ordered, they require schematics, protections, equitable connection when provided by the project, identified cable and proof by competent personnel. The boiler must be checked for fixing, valves, pipes and operation. The presence of the standard shower does not involve hot water; both voices must appear explicitly in the separate.
Bimini, soft top and covers
Bimini and soft top are separate accessories, such as console and bench covers. They mount and fold to control locks, interferences, visuals, height and storing. The canvases must drain without creating bags and not block bilge, passages or technical access. After a water test, fixations and vibrations are checked again. Each component receives inventory and instructions, because promotional photography does not show what is included.

Cockpit coating
The yard lists both cockpit cover and Flexiteek in the cockpit among the optional. The terminology should be clarified in order, specifying material and areas. We inspect edges, joints, adhesion, drainage and removable panels. The coating should not hide screws or prevent access to plants. The maintenance plan must follow the instructions of the mounted product, with photographs of the state to the delivery for subsequent comparisons.
Ski pole and poppiero sunbathing kit
Ski pole and additional stern cushions are optional. The pole requires identification, base, counterflange, locks and compatibility documented with the intended use; it does not deduce a ability to drive from the presence alone. The sunbed should be mounted to verify supports, stability and storage space. In both configurations must remain accessible ladder, compulsory safety equipment and technical access of the poppiera area.
Charges distribution
People, fuel, water, luggage and accessories must be distributed in compliance with the documents of the specimen. The indication eight or ten people does not guarantee that each set-up will offer the same steps. During the test, the crew’s position and the amount of liquids are noted, observing visual and response. In the gavones heavy objects are fixed; individual tops and devices remain accessible. Each option adds mass to be accounted for.
Test in documented water
Before departure, motorization, propellers, people, fuel, water, accessories, wind and sea are recorded. Start, alarms, government, trim, visibility, vibrations and installed utilities. Reentry control is felt, pipes, fixings and anomalous temperatures. If speed or consumption are measured, instrument and regime are indicated. A single output does not become a certification of the overall performance of the model.
Delivery minutes
The minutes lists documents, plates, keys, serials, motors, propellers, picture, steering, compass, lights, bilge, fuel, shower, toilet, refrigerator, table, ladder, pillows and every option. Abnormalities receive description, photography and correction time. In the new one compares the order; in the used one add invoices and maintenance. No voice must remain entrusted to memory or images of repertoire.
Coordinated maintenance plan
The program combines requirements of engines, government, batteries, bilge, fuel, water, toilet and accessories. After the remittance, loads, connections, pipes, drains, covers and fixings occur before the launch and after the first exit. Dates, hours and spare parts are recorded. Accessibility is a concrete purchasing criterion: a reachable component is controlled more easily and allows to identify first losses, corrosion or loosening.
Audit of subsequent changes
Each added accessory after delivery requires a new configuration control. For refrigerators, radios, boilers or counter sockets are updated schematics, protections, absorbing budgets and manuals. For soft tops, chimneys, ski poles or chimneys, fixtures, interferences, visuals, drainage and storing. A cockpit coating can also change access and inspection mode. The change is photographed, tested and connected to invoice, warranty and installation manager. A successful test at the time of assembly does not exhaust the work: after the first exits you recheck locks, temperatures, losses and signs of rubbing. This register allows to distinguish the original equipment from subsequent interventions and prevents an undocumented component from being attributed to the model or construction site.
Consistent configuration of the CAP 28 WA
The standard equipment is already articulated; the options should respond to the real program. Shadow, warm water and finishes increase comfort but also mass, wiring and maintenance. Dynamic activities require free space and verified fixations. The best configuration keeps access, steps and storage capacity, connects each component to a document and concludes delivery with repeatable tests. It is a more solid criterion than the amount of accessories installed.