Configuring the Tempest 38 Hair means turning a list of equipment into a verifiable system. The model measures 11.97 meters, accommodates up to 18 people and admits outboard for a total of 800 hp. These data do not say which engines, batteries or instruments are mounted on a single unit. The verification sequence must therefore start from the contractual distinction and follow each circuit from the delivery to the final test.
Data for the verification sequence
| Control | Summary |
|---|---|
| Length outside everything | 11,97 m |
| Maximum width | 3.54 m |
| Persons admitted | 18 |
| Dry mass | about 3,400 kg |
| Maximum power | 800 hp |
| Propulsion | outboard |
| Category CE | B |
| Sleeps | 2 |
| Planner | Technical department Cantieri Capelli |
Separate before any test
Engines, covers, coatings and utilities must be frozen in a document related to the specimen. Brand, model, serial, power supply, manual and warranty are noted for each device. The general board distinguishes standard and optional, but does not describe all installed variants. Without this base it cannot be established whether a component is missing or not ordered. The photos of the unit complete the minutes, without replacing the documents.

Outboard within 800 hp total
The 800 hp limit does not prescribe a combination of engines and does not show speed or consumption. The verification compares plates, total power, fixings and installation documents. We control wires, pipes and freedom of bandwidth movement. Elications, commands and tools must match the order. During testing people, levels, conditions and regimes are recorded, avoiding extending the result to other configurations.
Hydraulic steering with servo assistance
The servoassist hydraulic rudder is standard. At fast motors you inspect cylinders, fittings and steps, then you try a complete stroke observing any interference. The rotation of the outboard should not impact dashboards, cables or equipment. After navigation, you can search for each thread at the points you can reach. Fluid, drain and maintenance follow the system instructions really mounted, not intervals from different devices.
Plane, labels and alarms
The board does not set the mark and size of the screens. Each display, switch and command is then listed on board. Labels must match users and remain legible from the government position. The ignition, alarm sequence, and engine stop are tested. Any added electronics enters the schematic with fuse and declared connections. The view should not be reduced by accessories or covers.

Fuel tank of about 650 liters
The standard capacity is indicated in about 650 liters. Bocchettone, vent, indicator, access and pipe path are identified without attributing an undeclared material. After a controlled supply, smells and seal occur. The nominal capacity is not equivalent to available autonomy: the commander considers margin, route, load and conditions. The initial level is recorded when comparing test data.
Battery banks and drive
Number and capacity of batteries do not appear in the model card. At delivery you can identify all benches, switches, protections and utilities. Fixings, terminals and rooms must be clean and accessible. The voltage measures are carried out according to the manuals, both at rest and during the activation of the main utilities. The scheme must distinguish starting, services and any additional circuit actually present.
220 V dock charger
The 220 V dock charging is optional. If ordered, the technician checks socket, cable, protections, charger and connected batteries. The test respects the indicated connection sequence and disconnection, without using improvised adjustments. The absence of the system is not a non-compliance when the item is missing from the contract. The presence of a visible socket is not enough: the apparatus and diagram must confirm the complete function.

800 W Electric Verricello
The 800 W winch is included. Before activation the bow is released, the protection is identified and the status of the line is checked. A short test tests descent, recovery and stop keeping people away from moving organs. Gavones and drainage must remain free. At the end the line is secured according to procedure, without leaving the rest load supported only by the winch.
Water reserve of about 140 liters
The indoor shower is associated with about 140 liters declared. The control follows filling, pump, pipes, dispenser and drainage of the served area. After the test the rooms are inspected to exclude leaks. It does not promise a duration of the tank, because it depends on the use. For prolonged stop, cleaning and seasonal protection, the procedures of the installed components are applied, keeping fittings and filters accessible.
Optional 25 litre water heater
The water heat from about 25 liters does not belong to the base. If it appears in the separate, the supply, valves, input, output and points of use are identified. The start is only after checking the expected filling; during the cycle, there is a search for traphylaxis and anomalies. Declared capacity and presence do not allow to invent times or temperatures. The remittance should also include the specific procedure of the apparatus.

WC, washbasin and black water
The private toilet with WC and washbasin is standard, as well as the septic tank. The verification sequence identifies commands, adductions, valves, pipes and accesses available. It tests the operation according to the manual and inspects the local at the end. It is not declared an internal shower and should not be added by analogy with other models. The crew must know how to use and manage the waste before the first exit.
Drawer refrigerator approx. 95 liters
The 95 litre drawer refrigerator is standard. Model, power and protection are noted, then closing, guide and ventilation are checked. The cooling test respects the time and conditions indicated by the manufacturer, avoiding feedback based on noise alone. The drawer must open without blocking a passage and remain locked during navigation. Cleaning and technical access complete control.
Radio and four speakers
Radio and four speakers are part of the standard equipment. Each channel is tested at moderate volume, checking commands and fixings. The plant should not cover alarms or communications in maneuvers. Model, connection and fuse are recorded on the unit. If the shipowner requires changes, absorptions and protections must be recalculated and reported in the scheme, without occupying necessary access to other systems.

LED and underwater lights
LED courtesy lights are standard, while two underwater lights on the mirror are optional. The circuits are activated separately and each switch must be identified. If present, the underwater lights are controlled under the conditions permitted by the manufacturer, along with the passages in the mirror and the seal. They're not letting themselves inappropriately. Any replacements must maintain electrical compatibility and circuit protection.
Lavello in the guide cabinet
The government seat integrates a standard sink. The test opens the water, observes pressure, seal and discharge, then verify that doors and accesses do not interfere with the passage. The circuit must be traced back to the edge reserve and its protections. After use, check the area below. Objects placed in the furniture must not weigh on pipes or prevent inspection.
Fixed table and electric version
The fixed double table in teak is included. The alternative is an electric retractable table, always in teak, with additional cushion to form the sun. If you choose, the test checks complete movement, fine running, stability and procedure in the absence of current provided by the manual. The separate must clarify the replacement. People and objects stay away from the actuator, and the table is blocked before navigation.

Covers, A-frames and hard tops
A-frame in fiberglass, hard top and different bimini solutions are optional. There are a bimini per pozzetto on the A-frame, one with four poles in carbon and one with two poles in carbon. They should not be added without an approved configuration. For each cover you control attacks, joints, roofs and storage bag. No element must reduce the visual or accessibility of controls.
Covers and protective covers
Teak on well and passers-by and Flexiteek of the well are optional alternatives to describe with sample and extension. Console and seat covers are also available and for sunbathing and sitting poppieri. The delivery checks that each sheet corresponds to the expected point and can be secured without collecting water. The coating should not hide screws, drains or access necessary for maintenance.
Integrated planks and large gavone
Integrated poppie planks are standard. They control surface, fixtures, lifts and distances from outboards in different locations. The service ladder of the large gavone is optional: if present, opening, support and storage should be tested. The gavone must remain dry according to the project and free in drainage points. Heavy equipment is fixed and should not affect wires or pipes.

Standard bow propeller and tunnel
The tunnel for the bow propeller is indicated as standard, while the apparatus is a choice to be confirmed. The presence of the tunnel does not show that engine, control and power are installed. If the optional has been ordered, protections and battery are identified and short pulses comply with the manual are performed. Side assistance does not replace planning, wind control and crew communication.
Real mass and capacity of people
The approximately 3,400 kg declared are dry. Engines, 650 liters of fuel, 140 liters of water, optional, equipment, luggage and people build the operational mass. Eighteen is the maximum allowed, not the recommended load for each situation. All these elements are noted in the test. Heavy materials are distributed and fixed without covering batteries, valves, pumps or other inspection areas.
Testing in four stages
Dry identification, documents, tubulars, blanket and fixing are controlled. In the dock there are rudder, paintings, water, WC, refrigerator, winch, lights and accessories. At sea, commands and alarms are observed by recording load and conditions. On the return, the rooms are reopened to search for losses, smells, abnormal temperatures or loosening. Each relief is corrected and tested.
Check before each exit
The commander checks weather, documents, fuel with margin, water, batteries, bilge, rudder, engines, lights and fixing of the equipment. State and pressure of tubulars follow the manual. Steps and accesses remain free, while table, cushions and covers are secured. An updated distinction and a repeatable verification sequence allow you to manage the Tempest 38 without confusing real features, optional photos and undemonstrated performance.